Comparison of Measurement Technologies

Measurement Comparison Nuclear Laser Contact Ultrasonic
Corrects for fixture movement no no no yes
Measure all material colors yes no yes yes
Measure optically clear material yes no yes yes
Measure shiny reflective surfaces yes no yes yes
Measure non-reflective surfaces yes no yes yes
Operate reliably in dirty environments yes no no yes
Measure distance no yes yes yes
Requires precise standoff yes no yes no
Measure broad thickness/distance range no no no yes
Large spot size no no no yes
Fail safe features no no no yes
Measure soft materials/surfaces yes yes no yes
Ignore surface debris no no no yes
Measure leading and trailing surfaces of panel yes yes no yes
Affects surface of material measured no no yes no
Requires heads to retract no no yes no
Affected by product vibration no no yes no
Automatically detect if gages are incorrectly operating no no no yes
Scan in the cross machine direction yes yes no yes
Requires hazard warnings yes yes no no
Requires special regulations and permitting to install yes no no no
Requires expensive disposal yes no no no
Customer can purchase individual gages and components no yes yes yes
Measure product thickness and distance no yes yes yes
Full systems and system components available yes no yes yes
Requires high contact pressure no no yes no
Thickness measurement affected by density variation yes no yes no
Affected by background noise and radiation yes yes no no
Gage software prompts if gage is misaligned in collision no no no yes
Requires long sampling time to reduce affect of noise yes yes yes no

 

 

 